CẢM BIẾN ĐO MỨC APLISENS MODEL APC-2000ALW/L

119/55A Đường Phan Văn Hùm, Phường Trung Mỹ Tây, Thành phố Hồ Chí Minh
Hotline: 0962543178
Email: info@ctmarkvn.com

CẢM BIẾN ĐO MỨC APLISENS MODEL APC-2000ALW/L

Nhà sản xuất: APLISENS

  • Liên hệ
  • 292

Application
The APC-2000ALW/L level probe is applicable to measure liquid levels in tanks, deep wells or piezometers. The APC-2000ALW/L probe is applicable to measure levels of liquids containing contaminants or suspensions. A typical use for this probe is the measurement of levels of liquid waste in intermediate pumping stations, fermentation chambers, settling tanks etc. Because in submersible part of level probe is mounted only measuring sensor level probe can be use for measurement hot liquids max. 100°C.
Technical data
Accuracy:
±0,16%
Long-term stability: 0,16% for 2 years
Thermal error: < ±0,1% (FSO) / 10°C, max. ±0,4% (FSO) in the whole compensation range
Thermal compensation range:
      -25...100°C
      -40...80°C special version
Output actualization time: 0,5 s
Additional electronic damping: 0...60 s
Error due to supply voltage changes: 0,002% (FSO) / V
Electrical parameters
Power supply: 10...55 VDC (Exia: 10,5…30 VDC)
Output signal: 4...20 mA 2-wires + Hart protocol
Resistance required for communication: min. 240 W Load resistance
Operating conditions
Operating temperature range (ambient temp.):
-40...85°C
Medium temperature range:
      PU, ETEFE-R version: 0...40°C
      ETFE, PU+PTFE version: 0...80°C
      ETFE+PTFE version: 0...100°C