Nominal diameter
125 mm
Accuracy
±2.0% of full scale
Measuring system (SAMA class ⅢB)
Organic gas : 0 ~ 200°C
Inert gas : -200 ~ 700°C
Working range
Maximum scale value
Location of stem and mounting
Bottom connection, surface, case mounting lugs
Lower back connection, surface, case mounting lugs
Case and cover
Black glass reinforced thermoplastic (PBTB)
Solid front, blow-out back
Turret style case with built in rear flange lugs
Capillary
Capillary : 1.6/0.2 mm, 316SS
Armored tube : 7.5/5.5 mm, 304SS
Window
Polycarbonate
Dial
White aluminium with black graduation
Pointer
Black painted aluminium alloy
Stem
8.0, 10.0 and 12.0 mm
316SS and 316L SS
Stem, process connection
⅜", ½", ¾" PT, NPT and PF
Option
Special accuracy, ±1.0% of full scale