Nominal diameter: 100 and 150 mm
Accuracy: ±2.0% of full scale
Measuring system (SAMA class ⅢB):
Organic gas : 0 ~ 200°C
Inert gas : -200 ~ 700°C
Working range: Maximum scale value
Location of stem:
Bottom connection, direct
Bottom connection, surface, case mounting
Lower back connection, direct
Case: Black finished aluminium
Cover: Black finished aluminium
Window: Tempered safety glass
Dial: White aluminium with black graduation
Pointer: Black painted aluminium alloy
Stem: 8.0, 10.0 and 12.0 mm
316SS and 316L SS
Zero adjustment: Internal
Stem, process connection: 3/8", 1/2", 3/4" PT, NPT and PF
Option: ±1.0% of full scale