Design
Internal diaphragm, upper and under flange welded
no sealing and compact design
Accuracy
P2522 (63 mm) and P2523 (80 mm): ±1.6% of full scale
P2524 (100 mm): ±1.0% of full scale
Scale range (MPa, kPa, bar)
-0.1 ~ 0 to -0.1 ~ 2.4 Mpa
0 ~ 0.1 to 0 ~ 25 Mpa
Filling liquid
Silicone oil
Working pressure
Steady: 75 % of full scale (63 and 80 mm)
100 % of full scale (100 mm)
Over range protection: 130 % of full scale
Working temperature
Ambient: -20 ~ 65 °C
Fluid: Max. 100 °C
Degree of protection
EN60529/IEC529/IP65
Temperature effect
Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately ±0.5 % per 10 ℃ of full scale
Pressure connection (Gauge side)
Stainless steel (316SS)
Diaphragm
316L SS, Hastelloy-C, Tantalum, Monel
Diaphragm outer diameter
40 or 48 mm
Under flange (Process side)
316SS, 316L SS, Monel, Hastelloy-C
Process connection
¼", ⅜", ½" PT, NPT and PF
¼" PT and NPT (F)