Nominal diameter
100 and 160 mm
Accuracy
±1.0 % of full scale
±1.6 % of full scale
Scale range (MPa, kPa, bar)
0 ~ 4 kPa, 6 kPa, 10 kPa (P671 model)
0 ~ 25 kPa to 0 ~ 0.25 MPa (P672 model)
0 ~ 0.4 MPa to 0 ~ 2.0 MPa (P673 model)
Max. working pressure (Static pressure)
P671: Max. 4 MPa
P672 and P673: Max. 10 Mpa
Working temperature
Ambient: -20 ~ 65 °C
Fluid: Max. 100 °C
Degree of protection
EN60529/IEC529/IP67
Temperature effect
Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately ±0.5 % per 10 ℃ of full scale
Pressure connection
Stainless steel (316L SS), Monel and Hastelloy-C
Element
Bellows
Stainless steel (316L SS), Monel and Hastelloy-C
Case and cover
Stainless steel (304SS)
Window
Safety glass
Dial
White aluminium with black graduations
Filling liquid for differential cell
Silicone oil
Pointer
Black painted aluminium alloy (Zero adjustable)
Process connection
¼" NPT(F)
½" NPT(F) at 3-way and 5-way manifold valve
Standard accessories
Mounting bracket for 2" pipe
mounting with silver gray finished steel
Option
Remote seal - Not available with less than 40 kPa of differential pressure range
Mounting bracket with 316SS for 2" pipe
3-way and 5-way manifold valve
3-way and 5-way manifold valve (Monel)
Accuracy ±0.5 % of full scale