Applications
Hygienic temperature measurement in sanitary applications for the food industry and also biotech, pharmaceutical and cosmetics industries
Mechanical temperature display on pipelines, heat exchangers, bioreactors, tanks and mobile vessels
Temperature indication during cleaning and sterilisation
Special features
Safety through mechanical temperature indication
Easy cleanability due to case and wetted parts in hygienic design
Easy zero point setting
High overtemperature resistance
Description
The model TG58SA bimetal thermometer has been specifically designed for the requirements of sanitary applications.
The purely mechanical temperature transmission functions via a bimetal coil in the stem. For applications that require a measurement needing no auxiliary power, e.g. with mobile vessels, the TG58SA with case filling is particularly suitable.
On the back of the case, the zero point can be easily corrected.
The stem with its semi-spherical base, in conjunction with the aseptic process connections (e.g. clamp, VARINLINE®), enables a dead-space free connection to the process.
The TG58SA in hygienic design can be used for CIP (cleaning in place) and SIP (sterilisation in place) and in wash-down areas. The measuring instrument can thus be cleaned reliably and time-efficiently.
Especially for SIP applications, the thermometer shows a high overtemperature resistance and thus ensures a safe temperature measurement.
A variety of corresponding certification and documentation packages are available for GMP-compliant documentation. These include, for example, material proof or a list of single measured values.