Basic information
Standard EN 13190
Nominal size
100
160
Window
Laminated safety glass
Connection location
A73.1x0 Back mount (axial)
R73.1x0 Lower mount (radial)
S73.1x0 Back mount, adjustable stem and dial
F73.1x0 Version with capillary
S Standard (threaded connection) 1)
1 Plain stem (without thread)
2 Male nut
3 Union nut
4 Compression fitting (sliding on stem)
5 Union nut and loose threaded connection
6 Compression fitting (can be adjusted on either capillary or spiral protective sleeve)
7 Compression fitting on the case 1)
“Adjustable stem and dial” case version 90° swivelling and 360° rotatable
Dampening (option)
With liquid dampening (silicone oil)
With food-compatible liquid dampening
Materials (non-wetted)
Case, ring
Stainless steel 1.4301
Pointer
Aluminium, black, micro adjustment
Articulated joint (“adjustable stem and dial”) Stainless steel
Dial Aluminium (white)
1) Not applicable to version with capillary
Measuring element
Type of measuring element Gas-pressure inert gas filling, physiologically safe
Working range
Continuous load (1 year) Measuring range (EN 13190)
Short time (max. 24 h) Scale range (EN 13190)
Materials of the movement (wetted)
Combination of brass and stainless steel
Completely from stainless steel
Capillary
Diameter 2 mm
Length Capillary without spiral protective sleeve Max. 60 m
Capillary with spiral protective sleeve Max. 40 m
Capillary with spiral protective sleeve and PVC coating Max. 20 m
Minimum bending radius Capillary without spiral protective sleeve 6 mm
Capillary with spiral protective sleeve 20 mm
Capillary with spiral protective sleeve and PVC coating 30 mm
Spiral protective sleeve 7 mm
Material (non-wetted)
Stainless steel 1.4571
Measuring element
Mounting types for instruments with capillary
Surface mounting flange, stainless steel
Instrument mounting bracket, aluminium die-casting
Panel mounting flange, stainless steel
Triangular bezel with clamp, stainless steel
Contact bulb
Dimensions 120 x 22 x 12 mm
Mounting types
Mounting on pipes
Mounting on tanks
Accuracy specifications
Accuracy class Class 1 per EN 13190 at 23 °C ±10 °C ambient temperature