Display: Analog indicator, operation and alarm status LED
Accuracy:
±1.0 % at ambient temperature +20 °C (Indicator)
±2.5 % at ambient temperature -20 °C / +60 °C (Indicator)
±0.25 % at ambient temperature 0 °C ~ +50 °C (Current output)
Scale range: -0.1 ~ 0.1 MPa to -0.1 ~ 1.2 Mpa
Working temperature:
Ambient: -20 ~ 65 °C (Gas phase)
Storage: -50 ~ 60 °C maximum
System configuration: HART communication
Degree of protection: EN60529/IEC529/IP67
Pressure connection: Stainless steel (316SS)
Element: Stainless steel (316SS)
C-type bourdon tube
Case and cover: Stainless steel (304SS), Bayonet type
Window: Safety glass
Movement: Stainless steel (304SS)
Bimetal link (Temperature compensation)
Pointer: Black painted aluminium alloy
Process connection: G 1/2"
Helium leak rate: Tested to confirm leakage rates of less than 10 mbar L/sec
Electrical: Input power and current consumption 12 ~ 36 V DC input, Max. 60 mA@DC 24 V
Display: Operating and alarm status LED
Parameter input: HART configurator
Output:
Current output (4 ~ 20 mA, DC)
One instantaneous pressure rising alarm relay
Three pressure limit alarm relay
Relay contact rate
Contact resistance: Max. 70MΩ
Contact rating: 2 A 30 VDC, 0.5 A 125 DC (Res.load)
Max switching voltage: 220 VDC / 250 VAC
Max switching power: 60 W / 62.5 VA