Standard
EN 837-1
See Technical Information IN 00.05 for information on “Selection, installation, handling and operation of pressure gauges”.
Nominal size (NS)
Ø 160 mm [6"]
Accuracy class
0.6
0.25 (selectable for scale ranges ≤ 400 bar)
Grade 3A per ASME B40.100 (selectable for scale ranges ≤ 400 bar)
Scale ranges 0 ... 0.6 bar to 0 ... 1,600 bar [0 ... 10 psi to 0 ... 20,000 psi]
other units (e.g. psi, kPa) available or all other equivalent vacuum or combined pressure and vacuum ranges
Scale
Single scale
Mirror band scale
Pressure limitation
Steady: Full scale value
Fluctuating: 0.9 x full scale value
Short time: 1.3 x full scale value
Connection location
Lower mount (radial)
Process connection
G ½ B
Others on request
Permissible temperature
Medium
+200 °C [392 °F] maximum with unfilled instruments
+100 °C [212 °F] maximum with filled instruments (model 333.30)
Ambient
-40 … +60 °C [-40 ... +140 °F] with unfilled instruments
-20 … +60 °C [-4 ... +140 °F] with instruments with glycerine filling (model 333.30)
Temperature effect
When the temperature at the measuring system deviates from the reference Temperature
+20 °C [+68 °F]: ≤ ±0.4 %/10 °C [≤ ±0.4 %/18 °F] of full scale value
Case filling
Without
Glycerine
Wetted materials
Process connection
Stainless steel 316L
Pressure element
Stainless steel 316L
< 100 bar: Copper alloy, C-type
≥ 100 bar: Stainless steel 316L, helical type
≥ 1,000 bar: Ni-Fe alloy, helical type
Non-wetted materials
Case
Stainless steel
Safety level “S3” per EN 837: With solid baffle wall (Solidfront) and blow-out back
Ring
Bayonet ring, stainless steel
Triangular profile ring, polished stainless steel, with clamp
Movement
Stainless steel
Dial
Aluminium, white, black lettering
Instrument pointer
Aluminium, black (knife edge pointer)
Set pointer
Without
Aluminium, red
Window
Laminated safety glass
Ingress protection per IEC/EN 60529 IP65
Adjustment medium
Liquid for scale ranges > 25 bar; gas for scale ranges ≤ 25 bar
Gas for all scale ranges