Applications
* Critical industrial applications
* Demanding applications in research and development
* Harsh environments in the process industry
Special features
* Measuring ranges from 0 ... 10 to 0 ... 20,000 psi (0 ... 0.4 to 0 ... 1,600 bar)
* Non-linearity of up to 0.125 % of span
* Different output signals, e.g. 4 ... 20 mA, DC 0 ... 10 V, DC 1 ... 5 V and others
* Market-standard electrical connections, e.g. DIN EN 175301-803 A angular connector
* Common international process connections
Output signal
Signal type:
Current (2-wire):
4 ... 20 mA
20 ... 4 mA
Voltage (3-wire):
DC 0 ... 10 V
DC 0 ... 5 V
DC 1 ... 5 V
DC 0.5 ... 4.5 V
DC 1 ... 6 V
DC 10 ... 0 V
Ratiometric (3-wire):
DC 0.5 ... 4.5 V
Other output signals on request.
Permissible load in Ω
Current output (2-wire):
≤ (power supply - 7.5 V) / 0.023 A
with optional settling time of 1 ms:
≤ (power supply - 11.5 V) / 0.023 A
Voltage output (3-wire):
> maximum output voltage / 1 mA
Ratiometric output (3-wire): > 4.5k
Signal limiting (option): 4 ... 20 mA
Zero point: 3.6 mA / 3.8 mA / 4.0 mA
Full scale: 20 mA / 21.5 mA / 23 mA
DC 0 ... 10 V
Full scale: DC 10 V / DC 11.5 V
Voltage supply
Power supply: Maximum power supply for cULus approval: DC 35 V (DC 32 V with heavy-duty connector)
Current output (2-wire):
4 ... 20 mA: DC 8 ... 36 V (DC 12 ... 36 V with optional settling time of 1 ms)
20 ... 4 mA: DC 8 ... 36 V
Voltage output (3-wire):
DC 0 ... 10 V: DC 12 ... 36 V
DC 0 ... 5 V: DC 8 ... 36 V
DC 1 ... 5 V: DC 8 ... 36 V
DC 0.5 ... 4.5 V: DC 8 ... 36 V
DC 1 ... 6 V: DC 9 ... 36 V
DC 10 ... 0 V: DC 12 ... 36 V
Ratiometric output (3-wire): DC 0.5 ... 4.5 V: DC 5 V ±10 %
Dissipation loss:
Current output (2-wire): 828 mW (22 mW/K derating of the dissipation loss with ambient temperatures ≥ 100 °C (212 °F))
Voltage output (3-wire): 432 mW
Current supply
Current output (2-wire): Current signal, max. 25 mA
Voltage output (3-wire): max. 12 mA