Applications
* Machine building
* Hydraulic aggregates
* General industrial applications
* Food and beverage industry
Special features
* High-quality product
* Many configurations possible
* Flush process connection
* Large stocks for short delivery times
* Vacuum-tight

Signal type

Current (2-wire):  4 ... 20 mA

Current (3-wire): 0 ... 20 mA

Voltage (3-wire):

      DC 0 ... 10 V

      DC 0 ... 5 V

      Other output signals on request

Depending on the signal type the following loads apply:

      Current (2-wire) ≤ (power supply - 10 V) / 0.02 A

      Current (3-wire) ≤ (power supply - 3 V) / 0.02 A

      Voltage (3-wire) > max. output signal / 1 mA

Voltage supply: The power supply depends on the selected output signal

      4 ... 20 mA, 2-wire DC 10 ... 30 V

      0 ... 20 mA, 3-wire DC 10 ... 30 V

      DC 0 ... 10 V, 3-wire DC 14 ... 30 V

      DC 0 ... 5 V, 3-wire DC 10 ... 30 V

Reference conditions (per IEC 61298-1)
Temperature: 
59 ... 77 °F (15 ... 25 °C)
Atmospheric pressure: 12.47 ... 15.37 psi (860 ... 1,060 mbar)
Humidity: 45 ... 75 % r. h.
Power supply: DC 24 V
Mounting position: Calibrated in vertical mounting position with process connection facing downwards.

Accuracy at reference conditions:

      Standard ≤ ±0.5 % of span

      Option ≤ ±0.25 % of span 1)

      Including non-linearity, hysteresis, zero offset and end value deviation (corresponds to measured error per IEC 61298-2). Calibrated in vertical mounting position with process connection facing downwards.

Non-linearity (per IEC 61298-2): ≤ ±0.2 % of span BFSL

Non-repeatability: ≤ ±0.1 % of span

Temperature error in rated temperature range

Rated temperature range: 32 ... 176 °F (0 ... 80 °C)

Mean temperature coefficient of zero point:

      Measuring range > 0.25 bar ≤ 0.2 % of span/10 K

      Measuring range ≤ 0.25 bar < 0.4 % of span/10 K

Mean temperature coefficient of span: ≤ 0.2 % of span/10 K

Long-term drift: ≤ ±0.2 % of span/year

Adjustability of zero point and span:

      Adjustment is made using potentiometers inside the instrument.

      Not possible for cable outlet with ingress protection IP 68.

      Zero point ± 5 %

      Span ± 5 %

Time response

Settling time: ≤ 10 ms