Applications
* Machine building
* Hydraulic aggregates
* General industrial applications
* Food and beverage industry
Special features
* High-quality product
* Many configurations possible
* Flush process connection
* Large stocks for short delivery times
* Vacuum-tight
Signal type
Current (2-wire): 4 ... 20 mA
Current (3-wire): 0 ... 20 mA
Voltage (3-wire):
DC 0 ... 10 V
DC 0 ... 5 V
Other output signals on request
Depending on the signal type the following loads apply:
Current (2-wire) ≤ (power supply - 10 V) / 0.02 A
Current (3-wire) ≤ (power supply - 3 V) / 0.02 A
Voltage (3-wire) > max. output signal / 1 mA
Voltage supply: The power supply depends on the selected output signal
4 ... 20 mA, 2-wire DC 10 ... 30 V
0 ... 20 mA, 3-wire DC 10 ... 30 V
DC 0 ... 10 V, 3-wire DC 14 ... 30 V
DC 0 ... 5 V, 3-wire DC 10 ... 30 V
Reference conditions (per IEC 61298-1)
Temperature: 59 ... 77 °F (15 ... 25 °C)
Atmospheric pressure: 12.47 ... 15.37 psi (860 ... 1,060 mbar)
Humidity: 45 ... 75 % r. h.
Power supply: DC 24 V
Mounting position: Calibrated in vertical mounting position with process connection facing downwards.
Accuracy at reference conditions:
Standard ≤ ±0.5 % of span
Option ≤ ±0.25 % of span 1)
Including non-linearity, hysteresis, zero offset and end value deviation (corresponds to measured error per IEC 61298-2). Calibrated in vertical mounting position with process connection facing downwards.
Non-linearity (per IEC 61298-2): ≤ ±0.2 % of span BFSL
Non-repeatability: ≤ ±0.1 % of span
Temperature error in rated temperature range
Rated temperature range: 32 ... 176 °F (0 ... 80 °C)
Mean temperature coefficient of zero point:
Measuring range > 0.25 bar ≤ 0.2 % of span/10 K
Measuring range ≤ 0.25 bar < 0.4 % of span/10 K
Mean temperature coefficient of span: ≤ 0.2 % of span/10 K
Long-term drift: ≤ ±0.2 % of span/year
Adjustability of zero point and span:
Adjustment is made using potentiometers inside the instrument.
Not possible for cable outlet with ingress protection IP 68.
Zero point ± 5 %
Span ± 5 %
Time response
Settling time: ≤ 10 ms