Applications
Load monitoring
Load moment limitation
Hydraulic drive control
Pressure monitoring of hydrogen (model MH-3-HY)
Special features
For extreme operating conditions
Compact and robust design
Diagnostic function (option)
Signal clamping (option)
Customer-specific adaptations possible
Specifications
Accuracy specifications
Non-linearity per IEC 61298-2
Measuring ranges ≥ 40 bar [≥ 500 psi] ≤ ±0.25 % of span
Measuring ranges < 40 bar [< 500 psi] ≤ ±0.4 % of span
Accuracy
→ See “Max. measured error per IEC 61298-2”
Max. measured error per IEC 61298-2
Measuring ranges ≥ 40 bar [≥ 500 psi] ≤ ±1 % of span
Measuring ranges < 40 bar [< 500 psi] ≤ ±2 % of span
Medium temperature coefficient at -40 ... +100 °C [-40 ... +212 °F]
Zero point
Measuring ranges ≥ 40 bar [≥ 500 psi] ≤ ±0.15 % of span/10 K
Measuring ranges < 40 bar [< 500 psi] On request
Span ≤ ±0.08 % of span/10 K
Long-term stability per DIN 16086
Model MH-3
Measuring ranges ≥ 40 bar [≥ 500 psi] ≤ ±0.2 % of span/year
Measuring ranges < 40 bar [< 500 psi] ≤ ±0.3 % of span/year
Model MH-3-HY
Medium temperature range -40 ... +30 °C [-40 ... +86 °F]:
≤ ±1 % of span/year (typical)
≤ ±3 % of span/year (maximum)
Reference conditions
Per IEC 61298-1
Signal type
Model MH-3
Current (2-wire)
4 ... 20 mA
Voltage (3-wire)
DC 0 ... 10 V
DC 1 ... 5 V
DC 1 ... 6 V
Ratiometric (3-wire)
DC 0.5 ... 4.5 V
Model MH-3-HY
Current (2-wire)
4 ... 20 mA
Ratiometric (3-wire)
DC 0.5 ... 4.5 V
Load in Ω
Output signal 4 ... 20 mA ≤ (supply voltage - 10 V) / 0.02 A
Output signal DC 0 ... 10 V > 5 kΩ
Output signal DC 1 ... 5 V > 2.5 kΩ
Output signal DC 1 ... 6 V > 5 kΩ
Output signal DC 0.5 ... 4.5 V, ratiometric > 4.5 kΩ
Signal clamping
Yes
Diagnostic function
Yes
Voltage supply
Supply voltage
Output signal 4 ... 20 mA DC 10 ... 36 V
Output signal DC 0 ... 10 V DC 14 ... 36 V
Output signal DC 1 ... 5 V DC 8 ... 36 V
Output signal DC 1 ... 6 V DC 9 ... 36 V
Output signal DC 0.5 ... 4.5 V, ratiometric DC 4.5 ... 5.5 V
Current supply
Output signal 4 ... 20 mA < 30 mA
Output signal DC 0 ... 10 V < 10 mA
Output signal DC 1 ... 5 V < 10 mA
Output signal DC 1 ... 6 V < 10 mA
Output signal DC 0.5 ... 4.5 V, ratiometric < 10 mA
Dynamic behaviour
Settling time per IEC 61298-2
≤ 2 ms