Measuring element: Inert gas expansion system
Nominal size in mm: 100, 160
Instrument version
Back mount (axial)
Lower mount (radial)
Back mount (adjustable stem and dial)
Instruments with capillaries
Connection design
S Standard (male threaded connection)
1 Plain stem (without thread)
2 Male nut
3 Union nut
4 Compression fitting (sliding on stem)
5 Union nut and loose threaded connection
6 Compression fitting (can be adjusted on either capillary or spiral protective sleeve)
7 Compression fitting at the case
Unit (scale range) °C
Option: °F, °C/°F (dual scale)
Process connection: Plain, without thread; G ½ B; 1/2 NPT; G 1/2 female; 1/2 NPT female; M20 x 1.5; M24 x 1.5 female
others on request
Accuracy class: Class 1 per EN 13190 at 23 °C ±10 °C ambient temperature
Rated operating ranges and conditions: EN 13190
Stem diameter: 8 mm
Option: 6 mm; 10 mm; 12 mm
others on request
Working range
Continuous load (1 year): Measuring range (EN 13190)
Short time (max. 24 h): Scale range (EN 13190)
Window: Laminated safety glass
Contact bulb: 120 x 22 x 12 mm; Stainless steel 1.4571
Adjustable stem and dial
Stainless steel
Swivelling 90°
360° rotatable
Capillary
Ø 2 mm, stainless steel 1.4571, bending radius no less than 6 mm
Standard capillary: max. 60 m
Capillary with spiral protective sleeve: max. 40 m
Capillary with PVC coating: max. 20 m
Length to customer specification
Option: Armoured coating for capillary (Ø 7 mm spiral protective sleeve, flexible or PVC-coated)
Mounting types for instruments with capillary
Surface mounting flange, stainless steel
Instrument mounting bracket, aluminium die-casting
Panel mounting flange, stainless steel
Dampening (option): With liquid dampening
Reverse polarity protection: Yes
Process connection: Stainless steel 304SS
Stem: Stainless steel 316SS
Non-wetted materials
Case, ring: Stainless steel 304SS
Dial: Aluminium, white, black lettering
Pointer: Aluminium, black, adjustable pointer
Ingress protection per IEC/EN 60529: IP65
Permissible temperatures
Ambient: -20 … +60 °C [-4 ... +140 °F] without/with liquid dampening
Storage and transport
Without liquid dampening: -50 … +70 °C [-58 ... +158 °F]
With liquid dampening: -40 … +70 °C [-40 ... +158 °F]
Permissible operating pressure at the stem: max. 25 bar, static
Electrical connection: Angular connector