Applications
Working pressure measurement
Control pressure measurement
Special features
Developed for the extreme operating conditions in mobile working machines
Reliability and highest accuracy over the entire life cycle
Customer-specific adaptations and individualisation
High production capacities
Overload safety
≤ 400 bar [≤ 5,000 psi]: 3 times
600 bar [8,000 psi, 10,000 psi]: 2 times
1,000 bar: 1.5 times
The overload safety is based on the measuring range. Depending on the selected process connection and sealing, restrictions in overload safety can result.
Vacuum tightness
Yes
Signal type Signal
Current (2-wire)
4 ... 20 mA
Voltage (3-wire)
DC 1 ... 10 V
DC 1 ... 5 V
DC 0.5 ... 4.5 V
Ratiometric (3-wire)
DC 0.5 ... 4.5 V
Pulsewidth modulation PWM (3-wire)
10 ... 90 % pulse-duty factor
High level: DC 3 ... 12 V (selectable in 1 V steps)
Output frequency: 0.25 ... 2 kHz (selectable in 0.25 kHz steps)
Other output signals on request
Signal clamping (option)
The range of the output signal can be limited. For this purpose, a lower and an upper signal threshold are defined in the sensor electronics. If the output signal reaches these threshold values, the sensor outputs a defined, constant signal value. Therefore, in operation, unwanted pressure or signal ranges are filtered out.
Diagnostic function (option)
Permanent errors in the sensor electronics and temporary system overpressures can be output through defined constant output signals. A permanent error signal signifies a sensor defect and cannot be reset. The temporary error signal is reset as soon as the system pressure once again lies under the error threshold. In the application, one can therefore realise an efficient system diagnosis.
Load
Current (2-wire): ≤ (power supply - 7.8 V) / 0.022 A
Voltage (3-wire): ≥ max. output voltage / 1 mA
Ratiometric (3-wire): ≥ 4.5 kΩ
Pulsewidth modulation (3-wire): ≥ 10 kΩ
Voltage supply
Power supply
Max. power supply with UL approval: DC 35 V
Current output (2-wire)
4 ... 20 mA: DC 8 ... 36 V
Voltage output (3-wire)
DC 1 ... 10 V: DC 12 ... 36 V
DC 1 ... 5 V: DC 8 ... 36 V
DC 0.5 ... 4.5 V: DC 8 ... 36 V
Ratiometric output (3-wire)
DC 0.5 ... 4.5 V: DC 5 V ± 10 %
Pulsewidth modulation PWM (3-wire)
10 ... 90 % pulse-duty factor: (high level + DC 1 V) (min. DC 8 V) ... 36 V
Total current consumption
Current output (2-wire): ≤ 25 mA
Voltage output (3-wire): ≤ 10 mA
Ratiometric output (3-wire): ≤ 10 mA
Pulsewidth modulation (3-wire): ≤ 10 mA
Time response
Settling time per IEC 62594
1 ms
Signal damping (option)
2 / 4 / 9 / 18 / 37 / 75 / 150 ms
Switch-on time
200 ms
Reference conditions (per IEC 61298-1)
Temperature
15 ... 25 °C [59 ... 77 °F]
Atmospheric pressure
860 ... 1,060 mbar [12.5 ... 15.4 psi]
Air humidity
45 ... 75 % r. h.
Power supply
DC 24 V (DC 5 V with ratiometric output)
Mounting position
Calibrated in vertical mounting position with process connection facing downwards.
Accuracy specifications
Non-linearity (per IEC 61298-2)
≤ ±0.25 % of span (BFSL)
Long-term drift (per IEC 61298-2)
≤ ±0.1 % of span
Total error band
Including non-linearity, hysteresis, non-repeatability, zero point and full scale deviation, temperature error, temperature hysteresis and error through atmospheric air pressure fluctuations.
Operating conditions
Ingress protection (per IEC 60529 and ISO 20653)
see electrical connections
Permissible temperature ranges
Ambient: -40 ... +125 °C [-40 ... +257 °F]
Medium: -40 ... +125 °C [-40 ... +257 °F]
Storage: -40 ... +70 °C [-40 ... +158 °F]
Depending on the choice of sealing on the process connection, the electrical connection and UL approval, there may be limitations in the medium and ambient temperatures (for restrictions see “Process connections, sealings” and “Electrical connections”).
Vibration resistance (per IEC 60068-2-6)
40 g, 10 .... 2,000 Hz
Continuous vibration resistance (per IEC 60068-2-6)
10 g, 10 ... 2,000 Hz
Shock resistance (per IEC 60068-2-27)
100 g, 11 ms
EMC field
Current output (2-wire): 100 V/m (per ISO 11452-2)
Voltage output (3-wire): 100 V/m (per ISO 11452-2)
Ratiometric output (3-wire): 100 V/m (per ISO 11452-2)
Pulsewidth modulation (3-wire): 30 V/m (per IEC 61326-2-3)
Service life
100 million load cycles
Free-fall test (following IEC 60721-3-2)
Individual packaging: 1 m [3.28 ft]
Multiple packaging: 0.5 m [1.64 ft]
Materials
Wetted parts
304L, PH grade steel
Non-wetted parts
304L, electrical connection made of highly resistant glass-fibre reinforced plastic (PBT)