Features
It is suitable for uninterrupted gas supply. When one end is exhausted, it will automatically switch to the other end.
With air supply priority selection handle, you can set the priority air supply source
WR11 pressure reducing valve is adopted as the prototype valve, which can be used for corrosive and toxic gases
Wv4c diaphragm valve two-way, three-way valve is adopted as type prototype valve, with fewer links 20 µm filter element is installed at the inlet
Oxygen environment application options are available
The output pressure is within a certain range and has been set at the factory
Technical Data
Max Inlet Pressure: 3500 psig
Outlet Pressure Range: 85~115, 135~165, 185~60, 0~215, 235~265 psig
Internal Component Material
Valve seat: PCTFE
Diaphragm: Hastelloy
Filter mesh: 316L
Working Temperature: -40~+74 °C (-40~+165 °F)
Leakage Rate (Helium)
Inside the valve: ≤1x10-7 mbar l/s
Outside of valve: ≤1x10-9 mbar l/s
Connection: no visible bubbles
Discharge coefficient (Cv)
Pressure relief valve: Cv=0.2
Diaphragm valve: Cv=0.17
Parent port
Entrance port: 1/4 NPT
T export: 1/4 NPT
Pressure gauge port: 1/4 NPT
Working principle
WCOS11 series switching device includes two independent pressure reducing valves. Adjust the outlet pressure on the left and right sides by operating the linkage valve rod, that is when the left increases, the right decreases and the left supplies air; When the right increases, the left decreases and the right supplies air
When one side of the air supply is exhausted, it will automatically switch to the other side other air supply
Close the inlet diaphragm valve, open the pressure relief diaphragm valve, drain the air source on the exhausted side, and then replace it with a new air source
The priority air supply source can be selected by turning the switching handle.
Cleaning Technics
Standard (WK-BA)
All welded joints shall be cleaned according to the company’s standard cleaning and packaging specifications. When ordering, there is no need to add suffix
Oxygen Cleaning (WK-O2)
Product cleaning and packaging specifications for oxygen environment can be provided. This product meets the requirement of ASTM 93 C cleanliness. When ordering, please add O2 after the order number.